Littelfuse Startco PC-Interface Software
Motor and Feeder Protection

SE-Comm RIS allows you to view and edit setpoints remotely
Click here to view screen
captures of SE-Comm-RIS
in use.
SE-Comm-RIS
This program gives remote access to metering, control, data logging, and programming features on the MPS, MPU-32, and the FPU-32. Set points can be accessed individually or downloaded as a file. Metered data can be observed on a single screen. Logged data can be downloaded and saved on a computer. Protective curves can be plotted.

Version 3.0 and above allows custom curve points to be added by clicking on the graph, and shows the coordinates of the mouse pointer on screen. Version 3 also simplifies the process of opening an offline defaults file, and provides support for the latest firmware found on the MPS, MPU-32, and FPU-32. Added in Version 3.2 is the ability to change the state of the output relays, useful during troubleshooting or commissioning procedures. Version 3.5 is required for compatibility with the latest MPS, MPU-32, and FPU-32 firmware.

SE-COMM16
The SE-COMM16 communications software enables the user to communicate with the MPU-16A, FPU-16, and LP2000, and includes the Allen Bradley DF1 and Modbus RTU protocols. This version also includes support for data logging.

SE-PLOT allows you to generate performance curves based on your specifications
SE-PLOT
SE-Plot functionality is now included in SE-Comm-RIS.

Neutral-Grounding-Resistor Monitors

Screenshot of the SE-330 Monitoring software
Click here to view screen
captures of SE-MON330
in use.
SE-MON330
This software is used to receive data from SE-330, SE-330AU, and SE-330HV Neutral-Grounding-Resistor Monitors. It will display the relay's set points as well as measured values. The software features data logging of information at a selectable interval. SE-MON330 includes the NGR Monitor Set-Point Assistant, which provides set-point recommendations for the SE-325, SE-330, SE-330AU, and SE-330HV Neutral-Grounding-Resistor Monitors. Version 2.2 provides the ability to view a 10-event data log on SE-330 units with firmware version 10 or newer.

Trailing Cable Protection

Screenshot of SE-MON-GFGC in use.
SE-MON-GFGC
This program is used to receive data from an SE-145 Ground-Fault Ground-Check Monitor.

Temperature Monitoring

Screenshot of SE-Comm-RTD being configured.
Click here to view screen
captures of SE-Comm-RTD
in use.
SE-Comm-RTD
This program is used to communicate with up to 63 SIO-RTD modules. It can be used to configure inputs on SIO-RTD modules as either 4-20mA or one of several RTD types. The data collected can be exported. The software has an autostart feature so that the program will restart when the computer reboots. SE-Comm-RTD now includes plotting for up to eight input signals.